Alternative title | ELED-1 : Étalon isotopique de plomb à atomes égaux |
---|
Download | |
---|
DOI | Resolve DOI: https://doi.org/10.4224/crm.2021.eled-1 |
---|
Author | Search for: Meija, Juris1ORCID identifier: https://orcid.org/0000-0002-3349-5535; Search for: Methven, Brad1; Search for: Tong, Shuoyun2; Search for: Grinberg, Patricia1ORCID identifier: https://orcid.org/0000-0002-1167-6474; Search for: Mester, Zoltan1ORCID identifier: https://orcid.org/0000-0002-2377-2615; Search for: Yang, Lu1ORCID identifier: https://orcid.org/0000-0002-6896-8603 |
---|
Affiliation | - National Research Council of Canada
- State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, PR China
|
---|
Format | 3D, Material |
---|
Material type | Calibration solution |
---|
Subject | Canadian reference material; ELED-1; lead; isotopes of lead; atomic weight |
---|
Abstract | ELED-1 is a high purity isotopic lead Certified Reference Material (CRM). A unit of ELED-1 consists of 1 mL lead solution at 100 mg/kg in 2 % nitric acid that was prepared by mixing separated lead isotope materials to obtain approximately 1:1:1:1 ratio of lead-204, lead-206, lead-207, and lead-208. This material is intended as an isotopic standard of lead. Certified values for the isotopic composition and the atomic weight of lead have been established for this CRM. |
---|
Analytes | View analytesAnalyte | Quantity | Value | Expanded uncertainty | Unit | Type |
---|
lead | atomic weight | 206.2450 | 0.0004 | 1 | certified | lead-204 | isotopic abundance | 0.24675 | 0.00012 | mol/mol | certified | lead-206 | isotopic abundance | 0.25175 | 0.00006 | mol/mol | certified | lead-207 | isotopic abundance | 0.23958 | 0.00008 | mol/mol | certified | lead-208 | isotopic abundance | 0.26192 | 0.00011 | mol/mol | certified | 204Pb/206Pb | isotope ratio | 0.98015 | 0.00059 | mol/mol | certified | 207Pb/206Pb | isotope ratio | 0.95167 | 0.00036 | mol/mol | certified | 208Pb/206Pb | isotope ratio | 1.04043 | 0.00052 | mol/mol | certified | 204Pb/207Pb | isotope ratio | 1.02992 | 0.00072 | mol/mol | certified | 206Pb/207Pb | isotope ratio | 1.05078 | 0.00040 | mol/mol | certified | 208Pb/207Pb | isotope ratio | 1.09327 | 0.00069 | mol/mol | certified |
|
---|
Publication date | 2021-03-01 |
---|
Publisher | National Research Council of Canada |
---|
Copyright statement | - © 2021
National Research Council of Canada
|
---|
Access condition | |
---|
References | View items (8)- Guide to the expression of uncertainty in measurement (GUM) (1 September 2008). https://www.bipm.org/en/publications/guides.
- Meija, Juris, and Zoltán Mester. ‘Uncertainty Propagation of Atomic Weight Measurement Results’. Metrologia 45, no. 1 (8 January 2008): 53–62. https://doi.org/10.1088/0026-1394/45/1/008.
- Tong, Shuoyun, Juris Meija, Lian Zhou, Brad Methven, Zoltán Mester, and Lu Yang. ‘High-Precision Measurements of the Isotopic Composition of Common Lead Using MC-ICPMS: Comparison of Calibration Strategies Based on Full Gravimetric Isotope Mixture and Regression Models’. Analytical Chemistry 91, no. 6 (7 March 2019): 4164–71. https://doi.org/10.1021/acs.analchem.9b00020.
- Wang, Meng, G. Audi, F. G. Kondev, W.J. Huang, S. Naimi, and Xing Xu. ‘The AME2016 Atomic Mass Evaluation (II). Tables, Graphs and References’. Chinese Physics C 41, no. 3 (March 2017): 030003. https://doi.org/10.1088/1674-1137/41/3/030003.
- Sturgeon, R E, B Methven, S N Willie, and P Grinberg. ‘Assignment of Purity to Primary Metal Calibrants Using Pin-Cell VG 9000 Glow Discharge Mass Spectrometry: A Primary Method with Direct Traceability to the SI International System of Units?’ Metrologia 51, no. 5 (25 June 2014): 410–22. https://doi.org/10.1088/0026-1394/51/5/410.
- Dunstan, L.P., J.W. Gramlich, I.L. Barnes, and W.C. Purdy. ‘Absolute Isotopic Abundance and the Atomic Weight of a Reference Sample of Thallium’. Journal of Research of the National Bureau of Standards 85, no. 1 (January 1980): 1. https://doi.org/10.6028/jres.085.001.
- NIST SRM 997: Isotopic Standard for Thallium (23 July 1986). https://www-s.nist.gov/srmors/certificates/997.pdf.
- Yang, Lu, Shuoyun Tong, Lian Zhou, Zhaochu Hu, Zoltán Mester, and Juris Meija. ‘A Critical Review on Isotopic Fractionation Correction Methods for Accurate Isotope Amount Ratio Measurements by MC-ICP-MS’. Journal of Analytical Atomic Spectrometry 33, no. 11 (2018): 1849–61. https://doi.org/10.1039/c8ja00210j.
|
---|
Export citation | Export as RIS |
---|
Collection | Canadian Reference Materials and Methods |
---|
Record identifier | 8e233f68-31ef-4ebf-8e8e-92412d01615d |
---|
Record created | 2021-05-15 |
---|
Record modified | 2025-04-16 |
---|